Products centre >
Medium Voltage Switchgear >
GGJ
GGJ Main control center pannel
Low-voltage reactive power intelligent compensation device
Description
Overview
GGJ low-voltage reactive power compensation device using computer-aided design (CAD), the introduction of microcomputer control. inteligent implementation of inteligent tracking compensation,its reasonable structure, advanced technology, widely used in low-voltage power grid,improveower factor, reduce reactive power loss, improve power supply guality, is a new generation of energy-saving products.Dedicated to the 130-600K V three-phase transformer reactive power compensation.
Main feature
◇Intelligent controller control, full-featured. Reliable performance, automatic compensation: can increase the power factor to 0.9 or more;
◇Real-time display power grid power factor, display range: lag (0.00-0.99), ahead (0.00-0.99);
◇With over-voltage, harmonic, over compensation, system failure, lack of phase, overload and other comprehensive protection;
◇Memory has been set parameters, the system will not lose the parameters after power failure, the grid back to normal, automatically enter therunning state, no personnel on duty;
◇According to the grid load balance, to take the phase compensation or mixed compensation;
◇Anti-interference ability, can withstand the direct input from the grid amplitude of 2000V interference pulse, higher than the nationalprofessionalstandards;
Working conditions
◇Altitude:≤2000m;
◇Ambient temperature:-20℃~+45℃;
◇Relative humidity:≤90% at 20℃;
◇Installation environment:no harmful gases and steam,no conductive or explosive dust and serious mold.
The main technical parameters
◇Rated voltage: 0.38-0.66kV;
◇Rated frequency: 50Hz;
◇Rated capacity: 1-600kvar;
◇Applicable voltage range: (0.85-1.1) times the rated voltage;
◇Maximum allowable current: 1.3 times the rated current;
◇Control circuit: 1-16 loop;
◇Switching time: 1-150s 1 times, adjustable;
◇Work: automatic, continuous operation.
Distribution network detection function
◇real-time measurement and the whole point of the record transformer low-voltage side of the three-phase voltage, current, frequency, activepower, reactive power, power factor, active power, reactive power;voltage and current total distortion rate and 2-25 Subharmonic content;
◇RS-232 and RS-485 interface, can be handheld computer data copy, but also through the remote communication function to achieve wirele5:meter reading, device testing, parameter settings and time measurement data and records Data reading;
◇Data analysis function: the operatlon load data can be analyzed and processed, statistical query; comprehensive analysis of power supplyquality, calculate the voltage pass rate, power supply load rate, reliabilit.and maximum load rate; Query power factor, active power and reactive power; draw cach phase voltage,current,power factor curve; print comprehensive analysis and statistical reports.